Технические характеристики коммутатора Cisco DS-C9718-1K9:
Product compatibility |
Cisco MDS 9000 Family |
||
Software compatibility |
Cisco MDS NX-OS Software Release 7.3 or later |
||
Indicators |
Power supply LED FAN LED Supervisor LED Fabric LED Line-card module LED |
||
Protocols |
● Fibre Channel standards ● FC-PH, Revision 4.3 (ANSI INCITS 230-1994) ● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996) ● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999) ● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997) ● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998) ● FC-PI, Revision 13 (ANSI INCITS 352-2002) ● FC-PI-2, Revision 10 (ANSI INCITS 404-2006) ● FC-PI-3, Revision 4 (ANSI INCITS 460-2011) ● FC-PI-4, Revision 8 (ANSI INCITS 450-2008) ● FC-PI-5, Revision 6 (ANSI INCITS 479-2011) ● FC-FS, Revision 1.9 (ANSI INCITS 373-2003) ● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007) ● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007) ● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011) ● FC-LS, Revision 1.62 (ANSI INCITS 433-2007) ● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011) ● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001) ● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004) ● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006) ● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010) ● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001) ● FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004) ● FCP, Revision 12 (ANSI INCITS 269-1996) ● FCP-2, Revision 8 (ANSI INCITS 350-2003) ● FCP-3, Revision 4 (ANSI INCITS 416-2006) ● FCP-4, Revision 2b (ANSI INCITS 481-2011) ● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001) ● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003) ● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007) ● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011) ● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014) ● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014) ● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003) ● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006) ● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008) ● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010) ● FC-VI, Revision 1.84 (ANSI INCITS 357-2002) ● FC-SP, Revision 1.8 (ANSI INCITS 426-2007) ● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012) ● FAIS, Revision 1.03 (ANSI INCITS 432-2007) ● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008) ● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011) ● FC-FLA, Revision 2.7 (INCITS TR-20-1998) ● FC-PLDA, Revision 2.1 (INCITS TR-19-1998) ● FC-Tape, Revision 1.17 (INCITS TR-24-1999) ● FC-MI, Revision 1.92 (INCITS TR-30-2002) ● FC-MI-2, Revision 2.6 (INCITS TR-39-2005) ● FC-MI-3, Revision 1.03 (INCITS TR-48-2012) ● FC-DA, Revision 3.1 (INCITS TR-36-2004) ● FC-DA-2, Revision 1.06 (INCITS TR-49-2012) ● FC-MSQS, Revision 3.2 (INCITS TR-46-2011) ● Fibre Channel classes of service: Class 2, Class 3, and Class F ● Fibre Channel standard port types: E, F, FL, and B ● Fibre Channel enhanced port types: SD, ST, and TE ● FCoE standard port types: VE and VF ● IEEE 802.1Qbb-2011: Priority-based flow control (PFC) ● IEEE 802.3db-2011: MAC address control frame for PFC ● IEEE 802.1Qaz-2011: Enhanced transmission selection for bandwidth sharing between traffic classes (ETS and DCBX) ● IP over Fibre Channel (RFC 2625) ● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338) ● Extensive IETF-standards-based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs ● RFC 3643 and 3821 FCIP |
||
Chassis slot configuration |
● Line-card slots: 16 ● Supervisor slots: 2 ● Crossbar switching fabric slots: 6 ● Fan trays: 3 fan trays at the back of the chassis ● Power supply bays:16 |
||
Switching capability per fabric |
Number of Fabric Cards |
Front-Panel Fibre Channel Bandwidth per Slot |
FCoE Bandwidth per Slot |
1 |
256 Gbps |
220 Gbps |
|
2 |
512 Gbps |
440 Gbps |
|
3 |
768 Gbps |
660 Gbps |
|
4 |
1024 Gbps |
880 Gbps |
|
5 |
1280 Gbps |
1100 Gbps |
|
6 |
1536 Gbps |
1320 Gbps |
|
Performance and scalability |
● Up to 48-Tbps front-panel Fibre Channel switching bandwidth and 42 Tbps of FCoE bandwidth ● Supported Fibre Channel port speeds ◦ 2/4/8-Gbps autosensing; optionally configurable (2G not supported on 32-Gbps module) ◦ 4/8/16-Gbps autosensing; optionally configurable ◦ 8/16/32-Gbps autosensing; optionally configurable ◦ 10-Gbps Fibre channel ● Buffer credits: 48-port line-rate 16-Gbps advanced Fibre Channel modules: ◦ Up to 500 per port (dedicated-mode ports) standard ◦ Up to 4095 on an individual port (dedicated-mode ports with optional Cisco MDS 9700 Enterprise Package license activated) ● Buffer credits: 48-port line-rate 32-Gbps Fibre Channel modules: ◦ Up to 500 per port (dedicated-mode ports) standard ◦ Up to 8191 on an individual port (dedicated-mode ports with optional Cisco MDS 9700 Enterprise Package license activated) ● Ports per chassis ◦ Up to 768 2/4/8-Gbps, 4/8/16-Gbps, 8/16/32-Gbps, 10-Gbps Fibre Channel , or 10-Gbps FCoE ports, or up to 384 40-Gbps FCoE ports ● Ports per rack ◦ Up to 1152 2/4/8-Gbps, 4/8/16-Gbps, 8/16/32-Gbps or 10-Gbps Fibre Channel ports ● Port channel: Up to 16 ports (the channel can span any speed-matched port on any module in the chassis) |
||
Features and Functions |
|||
Fabric services |
● Name server ● Registered State Change Notification (RSCN) ● Login services ● Fabric configuration server (FCS) ● Broadcast ● In-order delivery |
||
Advanced functions |
● VSAN ● IVR ● Port channel with multipath load balancing ● QoS: flow based and zone based ● N-port ID virtualization (NPIV) |
||
Diagnostics and troubleshooting tools |
● POST diagnostics ● Online diagnostics ● Internal port loopbacks ● SPAN and RSPAN ● Fibre Channel traceroute ● Fibre Channel ping ● Fibre Channel debug ● Fabric Analyzer ● Syslog ● Online system health ● Port-level statistics ● Real-Time Protocol (RTP) debug |
||
Network security |
● VSANs ● ACLs ● Per-VSAN RBAC ● Fibre Channel zoning ◦ N-port World Wide Name (WWN) ◦ N-port FC-ID ◦ Fx-port WWN ◦ Fx-port WWN and interface index ◦ Fx-port domain ID and interface index ◦ Fx-port domain ID and port number ● FC-SP ◦ DH-CHAP switch-to-switch authentication ◦ DH-CHAP host-to-switch authentication ● Port security and fabric binding ● Management access ◦ SSHv2 implementing Advanced Encryption Standard (AES) ◦ SNMPv3 implementing AES ◦ SFTP ● Cisco TrustSec Fibre Channel link encryption |
||
Serviceability |
● Configuration file management ● Nondisruptive software upgrades for Fibre Channel interfaces ● Cisco Call Home ● Power-management LEDs ● Port beaconing ● System LEDs ● SNMP traps for alerts ● Network boot |
||
Reliability and availability |
● Online, nondisruptive software upgrades ● Stateful nondisruptive supervisor module failover ● Hot-swappable redundant supervisor modules ● Hot-swappable redundant fabric modules ● Hot-swappable 2N redundant power ● Hot-swappable fan trays with integrated temperature and power management ● Hot-swappable Enhanced Small Form-Factor Pluggable (SFP+) optics (2/4/8/10/16/32-Gbps Fibre Channel and 10 Gigabit Ethernet). 2G speeds not supported on 32G switching module. ● Hot-swappable switching modules ● Stateful process restart ● Any module, any port configuration for port channels ● Fabric-based multipathing ● Per-VSAN fabric services ● Online diagnostics ● Port tracking ● Virtual Routing Redundancy Protocol (VRRP) for management |
||
Network management |
● Access methods through Cisco MDS 9700 Series Supervisor-1E Module ◦ Out-of-band 10/100/1000 Ethernet port ◦ RS-232 serial console port ◦ In-band IP over Fibre Channel ● Access methods through Cisco MDS 9700 Series Fibre Channel switching module ● Access protocols ◦ CLI using console and Ethernet ports ◦ SNMPv3 using Ethernet port and in-band IP over Fibre Channel access ● Distributed device alias service ● Network security ◦ Per-VSAN RBAC using RADIUS-based and TACACS+-based authentication, authorization, and accounting (AAA) functions ◦ SFTP ◦ SSHv2 implementing AES ◦ SNMPv3 implementing AES ● Management applications ◦ Cisco MDS 9000 Family CLI ◦ Cisco Prime DCNM |
||
Programming interface |
● REST API–based NX-API ● Scriptable CLI ● Cisco Prime DCNM web services API ● Cisco Prime DCNM GUI |
||
Power and cooling |
● Power supplies (3000W AC) ◦ Input: 100 to 240V AC nominal (±10% for full range); 16A nominal; 50 to 60 Hz nominal (±3 Hz for full range) ◦ Output: 1451W 50V ±4% 28A, 3.4V ±4%/15A (100 to 120V AC input), 3051W 50V ±4% 60A, and 3.4V ±-4% 15A (200 to 240V AC input) ● Air flow ◦ The MDS 9718 provides 30 to 100 cubic feet per minute (CFM) total flow through each line-card slot depending on the line-card type and fan-speed setting. ◦ With the MDS 9718 using front-to-back cold-aisle and hot-aisle air flow, Cisco recommends that you maintain a minimum air space of 7 inches (17.78 cm) between walls, such as in a cabinet, on the sides, and on the top and bottom of the chassis. The chassis front air vents need a clearance of 12 inches, and the back air vents need a clearance of 36 inches from a solid obstruction such as a solid wall. |
||
Environmental |
● Temperature, ambient operating: 32 to 104°F (0 to 40°C) ● Temperature, ambient nonoperating and storage: –40 to 158°F (–40 to 70°C) ● Relative humidity, ambient (noncondensing) operating: 10 to 90% ● Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95% ● Altitude, operating: –197 to 6500 ft (–60 to 2000m) |
||
Physical dimensions (H x W x D) |
● Chassis dimensions (26 rack units [26RU]): 45.25 x 17.3 x 35 in. (114.9 x 43.9 x 88.9 cm) ● Cisco MDS 9700 48-Port 16-Gbps Fibre Channel Switching Module: 1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm) ● Cisco MDS 9700 48-Port 32-Gbps Fibre Channel line card; 1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm) ● Power supply (3000W AC): 22.04 x 3.95 x 1.6 in. (55.98 x 10.03 x 4.06 cm) ● Power supply (3000W DC): 23.54 x 3.95 x 1.6 in. (59.79 x 10.03 x 4.06 cm) ● Fabric-1 module: 32.40 x 2.02 x 10.22 in. (82.3 x 5.13 x 25.96 cm) ● Supervisor-1E module: 2.04 x 7.94 x 21.85 in. (5.18 x 20.17 x 55.5 cm) ● Fan tray: 36.17 x 5.15 x 1.87 in. (91.87 x 13.08 x 4.75 cm) ● SFP+: 0.49 x 0.54 x 2.22 in. (1.25 x 1.36 x 5.65 cm) |
||
Weight |
● Chassis (includes fans): 300 lb (136 kg) ● 48-port 16-Gbps Fibre Channel line card: 17 lb (7.71 kg) ● 48-port 32-Gbps Fibre Channel line card: 17.5 lb (7.94 kg) ● Power supply (3000W AC): 6 lb (2.7 kg) ● Fabric-1 module: 20 lb (9.07 kg) ● Supervisor-1E module: 8.5 lb (3.86 kg) ● Fan tray: 12.7 lb (5.76 kg) ● Supervisor blank cover: 1.1 lb (0.5 kg) ● Line-card blank cover: 4.5 lb (2.04 kg) |
||
Approvals and compliance |
● Safety compliance ◦ CE Marking ◦ UL 60950 ◦ CAN/CSA-C22.2 No. 60950 ◦ EN 60950 ◦ IEC 60950 ◦ AS/NZS 3260 ◦ IEC60825 ◦ EN60825 ◦ 21 CFR 1040 ● EMC compliance ◦ FCC Part 15 (CFR 47) Class A ◦ ICES-003 Class A ◦ EN 55022 Class A ◦ CISPR 22 Class A ◦ AS/NZS 3548 Class A ◦ VCCI Class A ◦ EN 55024 ◦ EN 50082-1 ◦ EN 61000-6-1 ◦ EN 61000-3-2 ◦ EN 61000-3-3 |